Choose the Best System for Your Needs
CaptiveAire offers two fire suppression systems with electronic Firestat detection.
CORE Fire Protection
Solid Fuel ApprovedWater-based fire suppression for commercial kitchens
- 360° Firestat electronic detection (NOT fusible links)
- Two Firestat ratings: 360°F (gas/electric) or 600°F (solid fuel)
- Microprocessor-based real-time monitoring with fault codes
- Integrated self-cleaning — daily wash-down of duct and plenum
- Total flood coverage with overlapping nozzle placement
- Unlimited water supply — prevents re-flashing
- Battery backup ensures safety during power outages
- Heat recovery coil option for energy savings
- Above-equipment mounting
Solid Fuel Recommendation: CORE Fire Protection is our only recommended fire suppression system for solid fuel applications (wood, charcoal, smokers), due to the complexities and inherent risks of live fire cooking. Requires 600°F Firestat.
ETL Listed to UL Standard 300 and ULC/ORD-C1254.6 | NFPA 96 & NFPA 17A Compliant
TANK Fire Suppression
Gas/Electric OnlyElectronic detection with wet chemical tank-based suppression
- 360° Firestat electronic detection (NOT fusible links)
- 360°F Firestat rating for gas/electric cooking
- Microprocessor-based real-time monitoring with fault codes
- 24/7 system pressure monitoring
- Independent supervised loops with redundancy and fault detection
- MAD Device (Mechanical Activation Device) for manual activation
- Battery backup for detection and suppression during power outages
- Simplified overlapping nozzle coverage
- Factory pre-piped system with optional field hookup
- Wall-mount configuration
Note: TANK systems are designed for gas and electric cooking equipment only. Not approved for solid fuel applications.
UL and ETL Listed to UL 300 | NFPA 96 & NFPA 17A Compliant
Firestat Temperature Ratings
CaptiveAire offers two Firestat temperature ratings to match your cooking application.
Standard Rating
Gas & Electric Cooking
Standard rating for conventional gas and electric cooking equipment including fryers, grills, ovens, and ranges. Operating temperatures typically stay well below 360°F during normal use.
Solid Fuel Rating
Wood, Charcoal & Smokers
Higher rating for solid fuel applications where normal operating temperatures exceed 360°F. Required for wood-fired ovens, charcoal grills, and smokers to prevent false activations.
Correct Firestat Rating is Critical
Using the wrong Firestat rating can result in either false activations (360°F on solid fuel) or delayed response in an emergency (600°F on gas/electric). During inspection, verify the installed Firestat rating matches the cooking application.
System Comparison
Compare CORE and TANK fire suppression systems side by side.
| Feature | CORE | TANK |
|---|---|---|
| Suppression Agent | Water with Surfactant | Wet Chemical |
| Water Supply | Unlimited (building water) | Tank-based |
| Detection | 360° Firestat — 360°F (standard) / 600°F (solid fuel) | 360° Firestat — 360°F (standard) |
| Firestat Rating | 360°F (gas/electric) or 600°F (solid fuel) | 360°F (gas/electric only) |
| Manual Activation | MAD Device | MAD Device |
| Monitoring | Microprocessor with fault codes | Microprocessor with fault codes |
| Battery Backup | Yes | Yes |
| Self-Cleaning | Yes — daily wash-down | No |
| Mounting | Above Equipment (in hood) | Wall Mount |
| Solid Fuel Approved | Yes (recommended) | No |
| Heat Recovery Option | Yes | No |
| Nozzle Type | OL-F Total Flood | OL-F Overlapping |
| ETL/UL Listed | UL 300, ULC/ORD-C1254.6 | UL 300, ULC/ORD-C1254.6 |
| NFPA Compliance | NFPA 96, NFPA 17A | NFPA 96, NFPA 17A |
IMPORTANT: Detection uses "360° Firestat (Electronic)" — NOT "Fusible Link". Manual Activation uses "MAD Device" — NOT "Pull Station".
Educational Videos
Learn about CaptiveAire fire suppression technology and kitchen fire safety.
Kitchen Fires 101
Fluid Dynamics Keeping Kitchens Safe
Solid Fuel Fire Protection
CORE Fire Protection
Technical Resources
Documentation, manuals, and technical bulletins for CaptiveAire fire suppression systems.
CCORE Documents
TTANK Documents
Inspection & Maintenance
Required inspection intervals for CaptiveAire fire suppression systems per NFPA 17A and NFPA 96.
| Monthly | Visual inspection: system armed, no visible damage, pressure gauges in normal range |
| Semi-Annual | Professional inspection per NFPA 17A: Firestat sensors, nozzle alignment, control panel, battery backup |
| Annual | Complete system inspection: Firestat temperature rating correct for application (360°F gas/electric or 600°F solid fuel), nozzle coverage, agent levels, documentation |
| As Needed | After system activation: Full inspection, recharge, and reset by certified technician |
Certifications & Approvals
Code Compliance
NFPA 96
Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations. Requires fire suppression for commercial cooking equipment.
View Requirements →NFPA 17A
Standard for Wet Chemical Extinguishing Systems. Governs design, installation, and maintenance of wet chemical suppression systems.
View Requirements →CaptiveAire Service & Inspection
Guspora is factory-certified for CaptiveAire CORE and TANK systems. Contact us for installation, inspection, maintenance, or recharge service.