Switchgear. Panels. Transformers. Grounding. Arc flash. Emergency systems. Every test, every standard, every jurisdiction.
Every electrical contractor knows these problems. We built Guspora to fix every one of them.
The NEC updates every three years and your jurisdiction adopts amendments on top of it. Keeping checklists current across NEC 110, 210, 220, and 250 means re-reading code books every cycle. Guspora updates every checklist item with the correct code citation automatically.
Building managers ask for panel directories and you dig through years of paper files. Circuit identification, breaker ratings, and load calculations live in notebooks that never leave the truck. Guspora makes every panel schedule digital, searchable, and tied to the building record.
NFPA 110 requires weekly no-load tests, monthly load tests, and annual load bank testing. Handwritten logs get lost, and when the AHJ asks for 12 months of records, you scramble. Guspora keeps every test logged digitally with automatic reminders and runtime tracking.
You shoot infrared images of panels and connections, but without annotation, comparison baselines, and trending, those thermal images are just colorful photos that prove nothing. Guspora lets you annotate hot spots, tag by panel and circuit, and track temperature trends over time.
You service 40 buildings with different panel types, different generator brands, and different AHJ requirements. Keeping track of which building needs what inspection and when is a full-time job. Guspora schedules, tracks, and reminds — across every building, every sub-trade.
Every feature was designed for the electrician standing at the panel with a meter in hand. Not a software developer who Googled NEC once.
Work the inspection your way. Guspora handles the report in the background.
Every inspection checklist item is linked to the specific NEC article or NFPA standard. Inspectors see the code requirement right next to the pass/fail checkbox — NEC 110.26 for clearances, 210.12 for AFCI, 250 for grounding. No flipping through code books on site.
Import infrared images directly into inspection records. Annotate hot spots, tag by panel and circuit, compare to baseline readings, classify severity per NETA standards, and track temperature trends over time.
Scan the barcode on any panel, generator, ATS, or device. Guspora pulls up the full history — last inspection, deficiencies, thermal scan records, and next due date. No searching through filing cabinets.
Every deficiency gets logged with severity, NEC or NFPA code reference, photo evidence, and a correction deadline. Automated reminders go to the building owner and your team until it is resolved.
Every photo is automatically tagged with GPS coordinates, timestamp, and device info. On-device face blurring runs by default — compliant with privacy regulations before the photo even saves.
Every customer gets their own portal showing panel status, generator test logs, upcoming inspections, thermal scan history, and deficiency tracking. They stop calling you because they can see everything.
No Wi-Fi in the electrical room? No problem. Guspora works fully offline on Android. Inspect panels, photograph deficiencies, and complete reports — everything syncs when you get signal back.
Hands-free inspection with Meta Ray-Ban, HK15, or phone-only mode. See checklists in your field of view, capture photos by voice command, and dictate notes without touching your phone — critical when both hands are on a meter.
Connect the tools you already use without burying your team in bolt-ons and exports.
Payment processing and invoicing built in.
LiveVoice calls, SMS reminders, and customer notifications.
LiveTransactional emails and report delivery.
LiveThermal imaging import and annotation sync.
BuildingGenerator monitoring data sync.
PlannedServiceTitan dispatches your electricians. Guspora helps them inspect, document, prove NEC compliance, and generate code-referenced reports from the electrical room. No per-report fees. No iPad requirements. No generic checklists.
Every electrical inspection type in a single system. Code-referenced checklists, manufacturer-specific items, and AI reporting for all of them.
Working space clearances, dedicated space above panel, illumination, and accessibility compliance per National Electrical Code.
Breaker physical condition, proper labeling of all circuits, directory accuracy, and legibility verification.
Equipment grounding conductor integrity, grounding electrode system, bonding jumpers, and ground fault path verification.
Conductor sizing verification against breaker rating, overcurrent protection coordination, and ampacity compliance.
Arc fault circuit interrupter trip testing, series and parallel arc detection verification, and code-required location compliance for dwelling units.
Ground fault circuit interrupter trip testing at all required locations — kitchens, bathrooms, garages, outdoors, crawl spaces, and unfinished basements.
Measured trip time testing against UL standards. GFCI devices must trip within 25 milliseconds at 6mA. AFCI devices tested per UL 1699 requirements.
Leakage current measurement on circuits, identification of ground fault sources, and verification of proper neutral-ground isolation.
Demand load calculations per NEC Article 220, power factor measurement, and capacity analysis for existing and planned electrical loads.
Total harmonic distortion measurement, neutral conductor loading assessment, and impact analysis on transformers and sensitive equipment.
Transformer visual inspection, insulation resistance testing, winding resistance, turns ratio verification, and oil analysis for liquid-filled units.
Switchgear visual inspection, insulation resistance testing, contact resistance, breaker timing tests, and protective relay calibration verification.
Start time verification, run duration minimum 30 minutes, voltage and frequency readings, coolant temperature, oil pressure, and fuel level check.
Generator operation under building load or supplemental load bank. Transfer switch exercise, voltage regulation, and frequency stability under load.
Full rated load test for minimum 2 hours. Coolant temperature, oil pressure, exhaust condition, and complete ATS exercise with timing verification.
Automatic transfer switch operation test — normal-to-emergency and retransfer. Fuel system integrity, day tank level, fuel quality sampling, and supply line inspection.
Air terminal placement, height, spacing, and physical condition verification. Inspection of all rooftop strike termination points per NFPA 780 zone of protection.
Down conductor routing, attachment, condition, and bend radius compliance. Cross-bonding of metallic bodies and verification of bonding connections.
Ground rod installation verification, ground resistance testing, grounding electrode conductor condition, and interconnection with building electrical ground.
Surge protective device installation, rating verification, indicator status, and coordination with lightning protection system and building electrical service.
Full infrared thermographic scan of electrical distribution equipment under load. Baseline establishment, comparative analysis, and severity classification per NETA guidelines.
Temperature differential measurement, severity classification (intermediate, serious, critical), priority ranking, and recommended corrective action timeline.
Torque verification of electrical connections at panels, switchgear, and distribution equipment using calibrated torque tools per manufacturer specifications.
Phase-to-phase temperature comparison for load imbalance identification. Neutral conductor thermal analysis and harmonic-related overheating detection.
All checklists are code-referenced and updated with each NEC cycle. Manufacturer-specific items available for major panel, generator, and switchgear brands.
Everyone who touches the job gets their own role-specific view without chasing updates over calls and PDFs.
Your Business Dashboard
Customer Compliance Portal
Jurisdiction Dashboard
Risk Assessment Portal
One building. Many trades. One operating system.
Tap through a real inspection checklist and watch the report workflow in action.
Launch Live Demo ->Founding Contractor is by application only. 50% off your first 6 months of Guspora service, plus 50% off GusporaCam for 12 months. Start with the 14-day money-back guarantee or apply directly.
“Milo protected our family for 10 years. Now he protects yours.”