PV commissioning. Rapid shutdown. Energy storage. Structural mounting. O&M annuals. Every NEC edition, every jurisdiction, every inspection.
Every solar contractor knows these problems. We built Guspora to fix every one of them.
Rapid shutdown requirements are completely different between the 2014, 2017, 2020, and 2023 NEC. You install to the wrong edition and the AHJ fails the inspection. Guspora tracks which NEC edition your jurisdiction has adopted and adjusts checklists automatically.
Some jurisdictions require structural, rough electrical, and final. Others want one inspection. Some require rapid shutdown testing with specific instruments. You show up and the inspector asks for documentation you did not know they needed. Guspora provides jurisdiction-specific requirements.
NFPA 855 is relatively new and most AHJs are still learning it. Spacing requirements, ventilation calculations, and fire detection depend on battery chemistry and capacity. Guspora provides NFPA 855 checklists with the calculations built in.
Annual O&M contracts require thermal imaging and I-V curve testing. The results end up on a technician laptop in a folder labeled "2025 scans" and nobody correlates them to specific modules. Guspora attaches thermal images to individual module records with GPS coordinates.
NEC 690.56 requires specific labels at service disconnects, rapid shutdown initiators, and source circuits. One missing label fails the inspection. Guspora walks the tech through every required label with photo verification for each one.
Every feature was designed for the installer on the roof at noon, not a software team that Googled NEC 690 once.
Guspora knows which NEC edition your jurisdiction has adopted. Rapid shutdown checklists, labeling requirements, and interconnection rules adapt automatically. No more guessing which code applies.
Work the inspection your way. Guspora generates the report in the background with the correct NEC article citations for the jurisdiction. Ready before you leave the roof.
Import IR images and attach them to individual module records with GPS coordinates. Track hot spots over time. Compare annual scans to baseline. Severity classification built in.
NFPA 855, NEC 706, and UL 9540 compliant battery storage inspection checklists. Spacing calculations, ventilation requirements, and fire detection verification.
Code-edition-specific rapid shutdown testing per NEC 690.12. Voltage drop verification, boundary definition, initiator location, and MLPE or UL 3741 compliance documentation.
Every required NEC 690.56 label verified with photo documentation. Service disconnect, rapid shutdown, source circuit, conduit, and arc-fault warning placards. Never fail an inspection for a missing label.
No cell signal on a rural rooftop? No Wi-Fi at the ground-mount site? Guspora works fully offline. Inspect, photograph, document. Everything syncs when signal returns.
Property owners see system performance, inspection history, warranty documentation, and upcoming O&M schedules. They stop calling because they can see everything.
Scoop Solar is project management with no code-referenced inspections. SolarNexus is a CRM with limited inspection capability. PVsyst is design software, not field inspection. No platform combines NEC-edition-specific solar inspections with AI reports and a full business OS.
Every solar and renewable energy inspection type in a single system. Code-referenced checklists adapted to your jurisdiction's currently adopted NEC edition.
String voltage measurement, inverter startup, grounding verification, rapid shutdown test, labeling per 690.56, interconnection per 705, arc-fault detection.
Initiator location, boundary definition, voltage drop to 30V within 30s (outside boundary), 80V within 30s (inside boundary per 2017+), MLPE or UL 3741 compliance.
String voltage, polarity, conductor sizing, overcurrent protection, disconnect operation, grounding electrode conductor, equipment grounding, conduit fill.
Interconnection method (supply-side vs load-side), bus bar rating, backfeed breaker position, conductor sizing, utility disconnect.
Roof attachment method, lag bolt pattern, flashing/waterproofing, ballast weight, wind load engineering, dead load calculation, rafter verification.
Setbacks from ridge/eaves/valleys (varies by jurisdiction), access pathways (3ft min), ventilation openings, fire classification compatibility.
Service disconnect placard, rapid shutdown label, system voltage label, source circuit label, conduit labels, arc-fault warning. UL 969 rated material.
Module condition (cracks, snail trails, hot spots), thermal imaging, soiling, inverter performance, string I-V curve, wiring integrity, ground fault.
Battery listing, spacing (NFPA 855 Table 9.3.2), ventilation, fire detection, signage, disconnect, thermal runaway protection, residential limits.
Listing verification, mounting, ventilation clearances, DC/AC disconnect, anti-islanding test, firmware, monitoring connectivity.
State of health, state of charge, cell balance, thermal management, ventilation, fire suppression (if required), capacity test.
Unit-level production verification, communication/monitoring, physical condition, grounding, rapid shutdown compliance.
EVSE listing, load management, solar-to-EV direct charging, panel capacity, GFCI, conductor sizing, signage.
Fencing, signage, grounding grid, equipment pad, trenching depth, conduit integrity, vegetation management, security.
Tower condition, blade inspection, guy wire tension, grounding, inverter/controller, anemometer calibration, yaw system.
All checklists adapt to your jurisdiction's currently adopted NEC edition. Standards shown are common references — Guspora handles local amendments automatically.
Everyone who touches the job gets their own role-specific view without chasing updates over calls and PDFs.
Your Business Dashboard
System Performance Portal
Jurisdiction Dashboard — Free
Risk Assessment — Free
One building. Many trades. One operating system.
Tap through a real inspection checklist and watch the report workflow in action.
Launch Live Demo ->Founding Contractor is by application only. 50% off your first 3 months, plus 50% off GusporaCam for 12 months. Start with the 14-day money-back guarantee or apply directly.
“Milo protected our family for 10 years. Now he protects yours.”