Structured cabling. Fire alarm circuits. Security systems. DAS. Access control. Nurse call. Every test, every certification, every standard.
Every low voltage contractor knows these problems. We built Guspora to fix every one of them.
You certify 200 cable runs, and the results live on the tester until someone remembers to export them. The GC asks for the certification report and you spend an hour finding the files, formatting them, and emailing them. Guspora imports test results and attaches them to the project record automatically.
BICSI RCDD requirements mean every cable, every pathway, every outlet needs to be documented in as-built drawings. You do the work in the field and then spend evenings updating spreadsheets and CAD files. Guspora structures the documentation as you work.
You pull the fire alarm circuits, the fire protection contractor inspects the panel, and nobody has a unified view of what was tested, when, and by whom. Guspora links fire alarm circuit inspections to the fire protection equipment record so everyone sees the same data.
IFC 510 requires annual in-building signal coverage testing with 24-hour battery backup verification. The report goes in a binder in the fire command room and nobody looks at it until the AHJ asks. Guspora stores DAS test results digitally with the building record.
Access control, CCTV, and intrusion detection inspections are done on whatever form the tech has in the truck. There is no industry-standard checklist. Guspora provides code-referenced checklists for every security system type.
Every feature was designed for the tech pulling cable at 6 AM, not a product manager who read a TIA standard once.
Work the inspection your way. Guspora generates the report in the background with TIA, BICSI, and NEC citations. Cable-by-cable results roll up into a building-level summary.
Import Fluke LinkWare results (CSV/PDF) and attach them to the project record. Track pass/fail per cable with rollup per floor, per building. Every test tied to the equipment record.
IFC 510 and NFPA 1221 compliant in-building signal coverage testing. Signal strength measurements, battery backup verification, and coverage maps stored with the building record.
Access control, CCTV, intrusion detection, and intercom inspections with code-referenced checklist items. UL 294, UL 681, and NFPA 101 egress compliance built in.
TR/MDF/IDF room inspections per TIA-569. Cable tray fill ratios, conduit fill calculations, separation from power, temperature and humidity documentation.
TIA-607 and BICSI N3 compliant bonding inspections. TBB, TGB, resistance measurements, and connection integrity verification with photo documentation.
No signal in the MDF room? No Wi-Fi above the ceiling grid? Guspora works fully offline. Test, photograph, document — everything syncs when you get signal back.
Hands-free inspection with Meta Ray-Ban, HK15, or phone-only mode. See checklists while both hands are pulling cable or terminating jacks.
DinoMyte and ServiceTitan are generic CRMs with no cable certification tracking, no TIA checklists, no DAS testing documentation, and no BICSI-referenced inspection items. Guspora is built for the tech in the ceiling, not the salesperson in the office.
Every low voltage inspection type in a single system. Code-referenced checklists with items specific to your jurisdiction's currently adopted codes.
Wiremap, length, insertion loss, NEXT, PSNEXT, return loss, ELFEXT, propagation delay, delay skew, ACR-N, ACR-F. Pass/fail per channel or permanent link model.
Insertion loss at 850/1300nm or 1310/1550nm, OTDR trace, connector endface inspection (IEC 61300-3-35), polarity verification, link loss budget.
Cable tray fill ratio, conduit fill per NEC Ch 9, bend radius, firestopping at penetrations, separation from power, TR room temperature and humidity.
Dedicated room, HVAC, lighting (50 fc min), grounding bus bar, cable management, rack loading, power (2 dedicated 20A circuits min), no water pipes.
TBB, TGB, bonding conductor sizing, resistance measurements, connection integrity.
Cable labels at both ends, patch panel labeling, outlet labeling, rack identification, pathway identification, documentation accuracy.
PSE output, PD compatibility, cable temperature under load, bundle derating, 4-pair vs 2-pair delivery, watt verification.
Cable jacket listing (CMP/CMR/CM), proper cable type for space classification, firestopping at rated barriers.
Card reader operation, credential database, door contacts, REX devices, emergency egress compliance, power supply and battery backup.
Camera coverage, recording storage and retention, night vision performance, network bandwidth, cybersecurity (passwords, firmware), NVR/DVR health.
Sensor placement and coverage, zone programming, central station comm test, backup path, battery backup, entry/exit timing, false alarm prevention.
Audio clarity, zone coverage, emergency override, ADA compliance (visual notification), backup power.
95% floor area / 99% critical area signal coverage, signal strength measurement, battery backup (24hr standby + 2hr full load), annual test.
Station placement, call prioritization, staff notification, battery backup, facility integration, ADA visual indicators.
Display resolution and brightness, audio intelligibility (STI), control system programming, source switching, network integration.
Sound pressure level uniformity, frequency spectrum, zone control, privacy index measurement.
Hot/cold aisle separation, cable management, fiber trunk routing, patch panel density, labeling, airflow obstruction check, redundant path verification.
AP placement, signal strength heat map, channel interference, roaming handoff, bandwidth verification, guest network isolation.
All checklists reference your jurisdiction's currently adopted codes. TIA, BICSI, NEC, and UL standards are common references — Guspora adapts to local amendments.
Everyone who touches the job gets their own role-specific view without chasing updates over calls and PDFs.
Your Business Dashboard
Customer Compliance Portal
Project Oversight
Jurisdiction Dashboard — Free
One building. Many trades. One operating system.
Tap through a real inspection checklist and watch the report workflow in action.
Launch Live Demo ->Founding Contractor is by application only. 50% off your first 3 months, plus 50% off GusporaCam for 12 months. Start with the 14-day money-back guarantee or apply directly.