Every Exit. Every System. Every Life Protected.

Built for life safety consultants, fire door inspectors, and ADA compliance specialists. Guspora handles emergency lighting, fire doors, egress audits, smoke control, ADA surveys, mass notification, and building code compliance — all on one platform with AI-powered reporting.

Join the Community
10
Sub-Trade Categories
8+
Code Standards
95%
Less Paperwork
$0
Per Report

What's Draining Your Billable Hours

Every life safety consultant knows these problems. We built Guspora to fix every one of them.

Multi-System Building Surveys Take All Day — Then All Night

You walk a 200,000 sq ft building checking egress paths, fire doors, emergency lighting, smoke dampers, and ADA routes. Then you sit at your desk until midnight compiling it into a report. Guspora generates the report from your voice notes before you leave the lobby.

ADA Litigation Risk With No Documentation Trail

Serial ADA lawsuits target buildings with undocumented accessibility deficiencies. Without structured surveys, photographic evidence, and remediation tracking, your clients are exposed every day the doors are open. Guspora creates a defensible compliance record automatically.

Fire Door Inventory Management Across Dozens of Buildings

NFPA 80 requires annual inspection of every fire-rated door assembly. A single hospital can have 400+ fire doors. Tracking them on spreadsheets means missed doors, lost records, and failed AHJ inspections. Guspora tracks every door with barcode scanning and full history.

Annual Testing Documentation That Nobody Can Find

Monthly 30-second tests, annual 90-minute tests, damper testing records, stairwell pressurization reports — the fire marshal asks for documentation and you spend an hour digging through filing cabinets. Guspora stores every test record with timestamps, photos, and code references.

Jurisdictional Code Variations That Change Building to Building

IBC vs. NFPA 101 vs. local amendments. NYC has LL26 photoluminescent egress requirements. California has Title 24. Chicago has its own fire code. Guspora checklists are code-referenced and jurisdiction-aware so you inspect to the right standard every time.

Built for Life Safety, Not Adapted From Something Else

Every feature was designed for life safety consultants who walk buildings for a living. Not repurposed from a fire alarm app that added a checkbox for ADA.

AI Reports

AI-powered reports

Work the inspection your way. Guspora handles the report in the background.

Code-Referenced

Code-Referenced Checklists for Every Sub-Trade

Not generic inspection forms. Every checklist item references the specific NFPA, IBC, ADA, or ASTM code section. Emergency lighting per NFPA 101 section 7.9. Fire doors per NFPA 80 section 5.2. ADA routes per 2010 ADA Standards. Always current.

Fire Doors

Fire Door Inventory & Tracking

Scan the barcode on any fire-rated door assembly. Guspora pulls up the full history — last inspection, deficiencies, gap measurements, label photos, and next due date. Track 400 doors across a hospital campus without a spreadsheet.

ADA Tools

ADA Barrier Survey & Remediation

Structured surveys covering routes of travel, doors, restrooms, parking, signage, and reach ranges per 2010 ADA Standards and ICC A117.1. Identify barriers, photograph them, and track remediation with deadlines and owner notifications.

Deficiency Pipeline

Deficiency Tracking & Follow-Up

Every deficiency gets logged with severity, code reference, photo evidence, and a correction deadline. Automated reminders go to the building owner and your team until it is resolved. Nothing falls through the cracks.

GPS + Photo

GPS-Stamped Photos with Face Blurring

Every photo is automatically tagged with GPS coordinates, timestamp, and device info. On-device face blurring runs by default — compliant with privacy regulations before the photo even saves. Essential for ADA restroom and building interior documentation.

Customer Portal

Building Owner Compliance Portal

Every client gets their own portal showing life safety status, ADA survey results, fire door conditions, upcoming inspections, and deficiency resolution progress. They stop calling you because they can see everything.

Offline + Android

Offline Android App

No Wi-Fi in the stairwell? No signal in the basement mechanical room? No problem. Guspora works fully offline on Android. Inspect, photograph, and complete reports — everything syncs when you get signal back.

Smart Glasses

Smart Glasses Integration

Hands-free inspection with Meta Ray-Ban, HK15, or phone-only mode. See checklists in your field of view, capture photos by voice command, and dictate notes while measuring door clearances or checking damper access panels.

Same Tools. One Platform.

Connect the tools you already use without burying your team in bolt-ons and exports.

Stripe

Payment processing and invoicing built in.

Live

Twilio

Voice calls, SMS reminders, and customer notifications.

Live

Postmark

Transactional emails and report delivery.

Live

CompanyCam

Photo sync for teams already using CompanyCam.

Building

ServiceTitan

Two-way sync for shops on ServiceTitan.

Planned

Stop Running Two Compliance Programs for One Building

Other platforms cover fire doors OR ADA — never both. They charge per report, lock you into iPads, and still make you type everything manually. Guspora gives you 10 sub-trade checklists, AI-generated reports, fire door tracking, ADA survey tools, and stakeholder portals — included.

$0
Per Report
15 min
Avg. Report Time
10
Sub-Trades Covered
Offline
Works Anywhere

10 Sub-Trades. One Platform.

Every life safety and ADA inspection type in a single system. Code-referenced checklists, jurisdiction-aware standards, and AI reporting for all of them.

Emergency Lighting & Exit Signs

Monthly 30-Second Functional Test

NFPA 101 §7.9.3

All emergency units illuminate, exit signs legible, battery charging indicators functional, and transfer to backup power verified.

Annual 90-Minute Battery Test

NFPA 101 §7.9.3.1

Full 90-minute discharge test, illumination levels verified at floor level, all units operational at end of test, and replacement scheduling for failures.

Illumination & Sign Visibility

NFPA 101 §7.10

Exit sign illumination intensity, viewing distance, mounting height, directional indicators, and photoluminescent sign charge verification.

Battery Condition Assessment

NFPA 101 §7.9

Battery age tracking, electrolyte levels, terminal corrosion, charging circuit function, and replacement scheduling per manufacturer guidelines.

Fire Door Inspection

Annual Fire Door Assembly Inspection

NFPA 80 §5.2

Door clearances (bottom, top, hinge side, latch side), hardware operation, glazing integrity, fire-rating labels, self-closing device, positive latching, and frame condition.

Gasket & Seal Verification

NFPA 80 §5.2.3

Smoke gasket condition, intumescent seal integrity, meeting-edge gaps on pairs, and astragal verification for double doors.

Rolling Fire Door Drop Test

NFPA 80 §5.2.4

Full operational drop test for rolling steel fire doors, sliding doors, and fire shutters. Reset verification and governor speed check.

Smoke & Fire Damper Testing

Fusible Link & Closure Test

NFPA 80 §19

Fusible link condition, full closure test from open position, blade seal integrity, and damper sleeve condition within duct penetration.

Access Door & Remote Release

NFPA 105

Access door verification for maintenance, remote release operation for smoke dampers, actuator function, and duct smoke detector interlock.

Stairwell Pressurization

Fan Operation & Differential Pressure

NFPA 92 / IBC §909

Stairwell pressurization fan startup, differential pressure measurement across closed doors, and minimum 0.05 in. w.c. verification.

Door Opening Force & Smoke Control

NFPA 92 §4.4

Door opening force not exceeding 30 lbf, smoke migration verification, and integration with fire alarm system activation.

Annual Commissioning Test

IBC §909.20

Full system commissioning including all fan speeds, damper positions, control sequences, and documentation of test results with engineer sign-off.

Means of Egress Audit

Travel Distance & Dead-End Evaluation

NFPA 101 §7.1-7.4

Maximum travel distance to nearest exit, dead-end corridor limits, common path of travel measurement, and exit remoteness verification.

Exit Capacity & Door Hardware

NFPA 101 §7.3-7.5

Occupant load calculation, exit capacity per occupant, panic hardware function, fire exit hardware listing, and door swing direction verification.

Illumination, Signage & ADA Compliance

NFPA 101 §7.6-7.7

Means of egress illumination at floor level, exit signage placement and visibility, tactile signage at exits, and accessible egress route verification.

ADA Accessibility Inspection

Ramp & Route of Travel Survey

ADA Standards / ICC A117.1

Ramp running slope (max 1:12), cross-slope (max 1:48), handrail graspability, landing dimensions, surface conditions, and edge protection.

Door Clearance & Hardware

2010 ADA Standards §404

Clear opening width (32 in. minimum), maneuvering clearance, threshold height (max 1/2 in.), hardware reach range, and opening force (max 5 lbf interior).

Restroom & Signage Assessment

2010 ADA Standards §603-703

Turning radius, grab bar placement, fixture heights, mirror mounting, accessible stall dimensions, tactile signage with Braille, and visual contrast.

Parking & Reach Range Verification

2010 ADA Standards §502

Van-accessible spaces, access aisle width, slope, signage height, route connection to building entry, and forward/side reach range at controls and outlets.

Mass Notification System

Voice Intelligibility Testing

NFPA 72 §24.4

Speaker coverage mapping, voice intelligibility score verification, ambient noise measurement, and message clarity across all notification zones.

Emergency Messaging & Integration

UL 2572

Pre-recorded and live message capability, integration with fire alarm system, priority override verification, and backup power operation.

Smoke Control Systems

Atrium Smoke Management

NFPA 92 §4.6

Exhaust fan capacity, makeup air balance, smoke layer height maintenance, and activation sequence from fire alarm and sprinkler waterflow.

Zoned Smoke Control & Performance Test

NFPA 92

Zone pressurization levels, damper position verification, airflow direction across barriers, and annual performance test with documented results.

Photoluminescent Egress Marking

Marking Luminescence & Placement

ASTM E2072 / NYC LL26

Luminescence intensity after charging, stairwell perimeter marking, handrail marking, landing designation, obstacle marking, and path continuity verification.

Charge Source & Maintenance

ASTM E2072

Ambient light charge verification, minimum luminance at 10 and 90 minutes after activation, cleaning schedule compliance, and replacement of degraded markings.

Building Code Compliance Survey

Occupancy & Construction Classification

IBC Ch. 3-6

Occupancy group classification, construction type verification, allowable height and area, fire separation distances, and mixed-use separation requirements.

Building Systems Assessment

IBC / IFC

Occupant load posting, fire protection system adequacy, means of egress compliance, accessibility provisions, and identification of code deficiencies requiring remediation.

All checklists are code-referenced and updated annually. Jurisdiction-specific amendments available for major metros including NYC, Chicago, and California.

Connected Stakeholder Portals

Everyone who touches the job gets their own role-specific view without chasing updates over calls and PDFs.

Service Provider

Your Business Dashboard

  • Schedule inspections across all 10 sub-trades
  • Track fire doors by barcode across every building
  • Generate AI reports with code citations
  • Invoice customers and track payments
  • Manage technician routes and workload

Building Owner

Customer Compliance Portal

  • View life safety and ADA status in one dashboard
  • See upcoming inspections and due dates
  • Track deficiency and ADA barrier remediation progress
  • Download inspection reports and certificates
  • Receive automated compliance reminders

AHJ / Fire Department

Jurisdiction Dashboard

  • Real-time life safety compliance across all buildings
  • Receive fire door and egress reports automatically
  • Track contractor licenses and credentials
  • Monitor deficiency resolution timelines
  • Included at no cost to code officials

Insurance Carrier

Risk Assessment Portal

  • Portfolio-level life safety compliance overview
  • ADA litigation risk assessment data
  • Fire door condition and deficiency severity data
  • Verified contractor credentials

Try It Right Now

Tap through a real inspection checklist and watch the report workflow in action.

Launch Live Demo ->

Built for Life Safety Consultants. By People Who Walk Buildings.

Founding Contractor is by application only. 50% off your first 6 months of Guspora service, plus 50% off GusporaCam for 12 months. Start with the 14-day money-back guarantee or apply directly.

“Milo protected our family for 10 years. Now he protects yours.”

Life Safety & ADA Inspection Software | Guspora™